12-09-2010 10:23 AM - edited 03-06-2019 02:26 PM
Hello,
I had this error on my cisco 4506 :
MET: %C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell A5A9 is duplicated, at positions 8194 and 81EE.
MET: %C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell A5A9 is duplicated, at positions 7D65 and 7DBF.
MET: %C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell E537 is duplicated, at positions 7939 and 7987.
MET: %C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell 4F4F is duplicated, at positions 54FD and 53DD.
I didn't find anything about this subject.
The IOS installed on my switch is cat4500-ipbasek9-mz.122-50.SG.bin
Could you help me to solve this issue?
Regards,
12-09-2010 06:10 PM
Hi Halima,
The error is most likely a parity problem on the supervisor engine. This can be transient and recovered through software, or may be a hardware parity error that can cause a crash if it continues. There is more information here CSCsg28982 which suggests the parity issues indicated.
If you continue to see more issues, I would suggest logging a case with TAC to have them provide further feedback.
/ijay
12-15-2010 01:34 AM
Hi,
Thanks a lot for your help.
Regards,