02-03-2016 11:29 AM
Hi guys,
probably this question was already posted.
There is a possibility to use more then one interface on the SNS-3415 or SN-3495 appliance for redundancy purpose ?
From ISE prospective this is not possible then all interface are routed interface.
In a VMware environment we can use the redundancy option of the VMware host.
Regards
Marco
Solved! Go to Solution.
02-14-2016 01:08 PM
Hi Marco,
After some internal discussions, I would like to clarify a couple of points:
Beside NIC teaming, which should be coming in next ISE release shortly,
It would also be possible to config more than one interface and use for redundancy. Think of two interfaces with unique IP. If one interface goes down, NAD, could attempt secondary interface.
Regards.
02-03-2016 12:34 PM
Marco, LAG/Ether-channel is not supported on ISE appliance interfaces. One can assign different services or profiling per interface, though wouldn't be for redundancy purpose.
Hosuk
02-07-2016 11:46 PM
Thx Hosuk.
Generally I see the 3415 appliance is not really redundant. Default the 3415 appliance will delivered with one hard drive and one power supply, for such a "central" unit a too little in my opinion. I understand why a redundant appliance must be always
purchased :-)
As feature request I wish at least a second HD and the possibility via software to configure LAG. If anyone have may same opinion, simply click on "i like".
02-10-2016 10:19 PM
I believe you may order a spare HD. And, NIC teaming/bonding is in the work.
02-14-2016 12:45 AM
Thx
02-14-2016 01:08 PM
Hi Marco,
After some internal discussions, I would like to clarify a couple of points:
Beside NIC teaming, which should be coming in next ISE release shortly,
It would also be possible to config more than one interface and use for redundancy. Think of two interfaces with unique IP. If one interface goes down, NAD, could attempt secondary interface.
Regards.
10-20-2016 08:34 AM
hi Hslai,
Can you please clarify "It would also be possible to config more than one interface and use for redundancy. Think of two interfaces with unique IP. If one interface goes down, NAD, could attempt secondary interface."
Can it be done for Monitoring node. If so what are configuration need to be done from ISE side and others like DNS.
Customer wanted to have functionality if one switch goes down , Mnt node can be reachable from other switch.
Please help
Discover and save your favorite ideas. Come back to expert answers, step-by-step guides, recent topics, and more.
New here? Get started with these tips. How to use Community New member guide