Hi @Jarurug ,
Then, in the @Marcel Zehnder 's script, just replace fvCEp with fvRsPathAtt
If that's what you needed, all the credit goes to him...
Hi Marcel, long time I've not been around, nice to see you again!
Hi @TomMik ,
As you have both old and new Spine connected to IPN anyway, you can simply configure the profiles for the new Spine, connect to Leaves, and let it being discovered. Then remove and clean the old Spine.
Regards
As long as the BDs are L2 only, no ERSPAN can be used in the Fabric.
When a BD is L3 and the ERSPAN destination IP is learned in the BD/EPG, ERSPAN will work.
Regards
Hi @joeharb ,
If you mean having the ERSPAN destination behind a L3Out connection, that is not possible. The destination must be learned as local Endpoint in the Fabric (meaning not L3Out).
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/ac...